System B Hydraulic Leak

If a leak develops in either pump, line or component of System B, the quantity decreases until it indicates approximately zero and System B pressure is lost. The System B Reservoir has one standpipe which supplies fluid to both the engine-driven pump and the electric motor-driven pump.

However, with fluid level at the top of the standpipe, fluid remaining in the System B Reservoir is sufficient for Power Transfer Unit operation. A leak in System B does not affect the operation of the Standby Hydraulic System.