BUS TRANSFER Switch

AUTO (guarded position) –

  • BTBs operate automatically to maintain power to AC Transfer Busses from any operating generator or extemal power
  • DC Cross Tie Relay avtomatically provides normal or isolated operation as required.

OFF – Isolates AC Transfer Bus 1 from AC Transfer Bus 2 if one IDG is supplying power to both AC Transfer Busses

  • DC Cross Tie Relay opens to isolate DC Bus 1 from DC Bus 2.

BACK