Generator (GEN) Switches

Three position switch, spring-loaded to neutral.

OFF – Disconnects IDG from related AC Transfer Bus by opening generator circuit breaker.

ON – Connects IDG to refated AC Transfer Bus by disconnecting previous power source and closing generator circuit breaker.