ENGINE START Switches GRD
For ground starts, arms selected igniter(s) to provide ignition when Engine Start Lever is moved to IDLE For inflight starts, arms both igniters to provide ignition when Engine Start Lever is moved to IDLE Releases to AUTO at start valve cutout. AUTO Ignition normally offBoth igniters are activated when Engine Start Lever is in IDLE and:
Provides automatic ignition to selected igniters when:
CONT Provides ignition to selected igniters when engine is operating and Engine Start Lever is in IDLEIn flight Provides ignition to both igniters when N2 is below idle and Engine Start Lever is in IDLE. FLT Provides ignition to both igniters when Engine Start Lever is in IDLE. |